Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int J Nanomedicine ; 19: 1909-1922, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38414522

RESUMO

Background: Radionuclides have important roles in clinical tumor radiotherapy as they are used to kill tumor cells or as imaging agents for drug tracing. The application of radionuclides has been developing as an increasing number of nanomaterials are used to deliver radionuclides to tumor areas to kill tumor cells. However, promoting the efficient combination of radionuclides and nanocarriers (NCs), enhancing radionuclide loading efficiency, and avoiding environmental pollution caused by radionuclide overuse are important challenges that hinder their further development. Methods: In the present study, a new small molecule compound (3-[[(2S)-2-hydroxy-3-(4-hydroxyphenyl)-1-carbonyl] amino]-alanine, abbreviation: HN, molecular formula: C12H16N2O5) was synthesized as a linker between radionuclide iodine-125 (125I) and NCs to enable a more efficient binding between NCs and radionuclides. Results: In vitro evidence indicated that the linker was able to bind 125I with higher efficiency (labeling efficiency >80%) than that of tyrosine, as well as various NCs, such as cellulose nanofibers, metal oxide NCs, and graphene oxide. Single-photon emission computed tomography/computed tomography imaging demonstrated the biological distribution of 125I-labeled NCs in different organs/tissues after administration in mice. Conclusion: These results showed an improvement in radionuclide labeling efficiency for nanocarriers and provided an approach for nanocarrier image tracing.


Assuntos
Radioisótopos do Iodo , Neoplasias , Camundongos , Animais , Radioisótopos do Iodo/química , Neoplasias/tratamento farmacológico , Modelos Animais de Doenças , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
BMC Pregnancy Childbirth ; 23(1): 718, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37817098

RESUMO

BACKGROUND: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the clinical value of the AI model for identifying fetal abnormalities during the first trimester. METHODS: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11-13+ 6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. RESULTS: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780-0.840), 0.760 (0.720-0.795), 0.766 (0.727-0.800), 0.807 (0.775-0.836), and 0.798 (0.764-0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585-0.788) and 0.729 (95%CI, 0.621-0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842-0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573-0.902) and 0.677 (95%CI, 0.494-0.859), respectively. CONCLUSIONS: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early screen for fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).


Assuntos
Síndrome de Down , Feminino , Gravidez , Humanos , Primeiro Trimestre da Gravidez , Síndrome de Down/diagnóstico , Estudos Retrospectivos , Síndrome da Trissomía do Cromossomo 18 , Inteligência Artificial , Ultrassonografia Pré-Natal/métodos , Feto/diagnóstico por imagem , Segundo Trimestre da Gravidez
3.
BMC Med ; 21(1): 292, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37545008

RESUMO

BACKGROUND: Folic acid (FA) supplementation is associated with a lower risk of the neural tube and heart defects and is recommended for women of childbearing age. Although there are detailed recommendations, differences in the initiation time and duration of FA supplementation remain poorly studied. METHODS: A multicentre prospective study of 17,713 women was conducted. The incidence of congenital malformations in women taking a recommended dosage (e.g. 0.4 or 0.8 mg/day) of FA was compared with that in women without supplementation. The predicted probability of malformations by the initiation time and duration of FA use was estimated to determine optimal options. RESULTS: Periconceptional FA supplementation was associated with a lower and insignificant risk of congenital malformations (1.59% vs. 2.37%; odds ratio [OR] 0.69; 95% confidence interval [CI]: 0.44-1.08), heart defects (3.8 vs. 8.0 per 1000 infants; OR, 0.47; 0.21-1.02), and neural tube defects (7.0 vs. 11.5 per 10,000 infants; OR, 0.64; 0.08-5.15). FA use after pregnancy provided greater protection against total malformations. Statistically significant associations were found in women who initiated FA supplementation in the first month of gestation (OR, 0.55; 95% CI: 0.33-0.91) and in those who supplemented for 1 to 2 months (OR, 0.59; 95% CI: 0.36-0.98). Similar results were found for heart defects. The optimal initiation time was 1.5 (optimal range: 1.1 to 1.9) months before pregnancy and a duration of 4.0 (3.7 to 4.4) months was reasonable to achieve the lowest risk of congenital malformations. Heart defect prevention required an earlier initiation (2.2 vs. 1.1 months before pregnancy) and a longer duration (4.7 vs. 3.7 months) than the prevention of other malformations. CONCLUSIONS: The timely initiation of FA supplementation for gestation was associated with a decreased risk of congenital malformations, which was mainly attributed to its protection against heart defects. The initiation of FA supplementation 1.5 months before conception with a duration of 4 months is the preferred option for congenital malformation prevention. TRIAL REGISTRATION: Chictr.org.cn identifier: ChiCTR-SOC-17010976.


Assuntos
Ácido Fólico , Complexo Vitamínico B , Gravidez , Lactente , Feminino , Humanos , Cuidado Pré-Concepcional , Estudos Prospectivos , Suplementos Nutricionais
4.
Acta Obstet Gynecol Scand ; 102(6): 735-743, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37073619

RESUMO

INTRODUCTION: The potential teratogenic risk of traditional Chinese medicine (TCM) is of widespread concern; however, related evidence is largely absent in humans. This study aimed to compare the prevalence of congenital malformations between pregnant women with and without TCM exposure. MATERIAL AND METHODS: This was a multicenter prospective cohort study of 17 713 women who participated in a survey on periconceptional TCM exposure. Primary outcome was congenital malformations diagnosed from a survey conducted on the day 42 after delivery. RESULTS: A total of 16 751 pregnant women with 273 congenital malformations were included in the analysis. Fetuses exposed to TCM had an increased risk of congenital malformations compared to those without exposure (odds ratio [OR] 2.10; 95% confidence interval [CI] 1.09-4.02) after controlling for potential confounders. There were significant associations with congenital malformations in women with early pregnant exposure (OR 2.04, 95% CI 1.00-4.20) and for those who received ≥2 TCM formulas (OR 5.84, 95% CI 1.44-23.65). Pre-pregnancy TCM exposure was significantly associated with an increased risk of congenital heart defects (OR 12.69; 95% CI 3.01-53.51). CONCLUSIONS: Periconceptional TCM exposure is associated with an increased risk of congenital malformation. This effect was cumulative and sensitive to periconceptional age. Therefore, TCM deserves more attention and should be used cautiously for pregnant women and those trying to become pregnant.


Assuntos
Anormalidades Induzidas por Medicamentos , Anormalidades Congênitas , Cardiopatias Congênitas , Complicações na Gravidez , Feminino , Gravidez , Humanos , Estudos Prospectivos , Medicina Tradicional Chinesa/efeitos adversos , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/complicações , Exposição Materna/efeitos adversos , Anormalidades Induzidas por Medicamentos/epidemiologia , Anormalidades Induzidas por Medicamentos/etiologia , Anormalidades Congênitas/epidemiologia , Anormalidades Congênitas/etiologia
5.
BMC Pregnancy Childbirth ; 22(1): 738, 2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-36184592

RESUMO

OBJECTIVES: To study the correlations between facial profile markers and crown-lump length (CRL) in a Chinese population, and to evaluate the clinical value of these markers for abnormal fetuses during the first trimester (11 to 13+6 gestational weeks).  METHODS: The facial profile markers were as followings: inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial maxillary angle (FMA), frontal space (FS) distance and profile line (PL) distance. These markers were measured in facial mid-sagittal section through ViewPoint 6 software. The diagnostic value of these markers for abnormal fetuses was assessed by receiver operating characteristic (ROC) curves. RESULTS: According to the first-trimester scanning (FTS) and follow-up, 31 fetuses were enrolled in the abnormal group, including 14 cases of trisomy 21, 7 cases of trisomy 18, 10 cases with cleft lip and palate (CLP), and 1000 normal fetuses were selected. Among the normal fetuses, the IFA, FS distance and PL distance had negative correlations with CRL. The MNM angle and FMA had positive correlations with CRL. The mean IFA values for fetuses with trisomy 21 and trisomy 18 were 74.11° (standard deviation (SD) 7.48) and 69.88° (SD 7.08), respectively, which were significantly smaller than the normal fetuses (p = 0.013; p = 0.003). The mean MNM angle of fetuses with trisomy 18 and CLP were 6.98° (SD 2.61) and 9.41° (SD 2.57), respectively, which were significantly greater than the normal fetuses (p = 0.005; p < 0.001). The mean FMA values of trisomy 18 fetuses were 63.95° (SD 4.77), which was significantly smaller than the normal fetuses (p < 0.001). The mean FS distance of CLP fetuses was -0.22 mm (SD 1.38), which was significantly smaller than the normal fetuses (p < 0.001). The mean PL distance of trisomy 21, trisomy 18 and CLP fetuses were 2.89 mm (SD 0.41), 2.91 mm (SD 0.56) and 2.71 mm (SD 0.37), respectively. The difference with the normal fetuses had no statistical significance (p = 0.56; p = 0.607; p = 0.54). CONCLUSIONS: Fetal facial profile markers had excellent correlations with CRL during the first trimester. IFA had certain clinical significance in detecting trisomy 21. FMA, IFA and MNM angle were reliable indicators for screening trisomy 18. The abnormal MNM angle and FS distance could be used as sensitive indicators for CLP. However, PL distance was not the best markers for trisomy 21, trisomy 18 and CLP.


Assuntos
Fenda Labial , Fissura Palatina , Síndrome de Down , Síndrome de Down/diagnóstico , Feminino , Feto , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Trissomia , Síndrome da Trissomía do Cromossomo 18/diagnóstico , Ultrassonografia Pré-Natal
6.
BMC Pregnancy Childbirth ; 21(1): 324, 2021 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-33894762

RESUMO

BACKGROUND: To establish reference ranges of fetal facial profile markers and study their correlations with crown-rump length (CRL) during the first trimester (11 ~ 13+ 6 weeks' gestation) in a Chinese population. METHODS: Ultrasonographic images of measuring fetal nuchal translucency (NT) were retrospectively selected randomly in normal fetuses whose parents were both Chinese. The facial markers included inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial maxillary angle (FMA) and profile line (PL) distance. These markers were measured through ViewPoint 6 software by two experienced sonographers. RESULTS: Three hundred and eighty fetuses were selected. The ICCs (95 % CI) of intra-operator 1 reproducibility of IFA, MNM angle, FMA, PL distance were 0.944 (0.886 ~ 0.973), 0.804 (0.629 ~ 0.902), 0.834 (0.68 ~ 0.918) and 0.935 (0.868 ~ 0.969), respectively. The ICCs (95 % CI) of intra-operator 2 reproducibility of IFA, MNM angle, FMA, PL distance were 0.931 (0.857 ~ 0.967), 0.809 (0.637 ~ 0.904), 0.786 (0.600 ~ 0.892) and 0.906 (0.813 ~ 0.954), respectively. The ICCs (95 % CI) of inter-operator reproducibility of IFA, MNM angle, FMA, PL distance were 0.885 (0.663 ~ 0.953), 0.829 (0.672 ~ 0.915), 0.77 (0.511 ~ 0.891) and 0.844 (0.68 ~ 0.925), respectively. The average ± SD of IFA, MNM angle, FMA and PL distance were 80.2°±7.25°, 4.17°±1.19°, 75.36°±5.31°, 2.78 ± 0.54 mm, respectively. IFA and PL distance significantly decreased with CRL, while MNM angle and FMA significantly increased with CRL. CONCLUSIONS: It was feasible to measure fetal facial markers during the first trimester. In Chinese population, the reference ranges of IFA, MNM angle, FMA and PL distance were 80.2°±7.25°, 4.17°±1.19°, 75.36°±5.31°, 2.78 ± 0.54 mm, respectively, and the measurements were found to correlate with CRL.


Assuntos
Estatura Cabeça-Cóccix , Face , Feto/diagnóstico por imagem , Medição da Translucência Nucal/métodos , Ultrassonografia Pré-Natal/métodos , Adulto , China/epidemiologia , Precisão da Medição Dimensional , Face/anormalidades , Face/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Reprodutibilidade dos Testes
7.
J Clin Ultrasound ; 49(4): 307-314, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33665816

RESUMO

OBJECTIVE: To evaluate the clinical value of three-dimensional ultrasound (3D-US) with reformatting technique in the diagnosis of fetal cleft lip/palate (CL/P), especially those involving the secondary palate. METHODS: A total of 113 fetuses suspected with cleft lip (CL) on two-dimensional ultrasound (2D-US) were further evaluated by 2D-US and 3D-US with reformatting technique, in order to clarify the type of oral cleft. Lesions were classified as cleft lip (CL), cleft lip and alveolus (CLA), and cleft lip and palate (CLP) (including primary and secondary palate). All fetuses were followed until birth or termination of pregnancy. The diagnostic accuracies of 2D-US and 3D-US with reformatting technology were compared. RESULTS: Both 2D-US and 3D-US with reformatting successfully detected CLs in the final 103 participants. Among these, 29, 25, and 49 cases were confirmed to have CL, CLA, and CLP, respectively. CL, CLA, and CLP were diagnosed by 2D-US in 34, 66, and 3 cases, respectively, and by 3D-US with reformatting technology in 31, 27, and 45 cases, respectively. The sensitivities of 2D-US and 3D-US with reformatting technology in the diagnosis of CLA were 80% (20/25) and 92.0% (23/25), respectively, and the difference was not statistically significant. For CLP, however, the sensitivities were 6.1% (3/49) and 91.8% (45/49), respectively (P < .001). CONCLUSIONS: Both 2D-US and 3D-US with reformatting technique have high diagnostic accuracy for CL and CLA. However, 3D-US has a much higher diagnostic accuracy for CLP.


Assuntos
Fenda Labial/diagnóstico por imagem , Fissura Palatina/diagnóstico por imagem , Doenças Fetais/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Recém-Nascido , Masculino , Gravidez , Ultrassonografia Pré-Natal/métodos
8.
Sci Rep ; 6: 30189, 2016 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-27452835

RESUMO

Cis-stilbene combretastatin A-4 (CA-4) and a large group of its derivant compounds have been shown significant anti-angiogenesis activity. However the side effects even the toxicities of these chemicals were not evaluated adequately. The zebrafish model has become an important vertebrate model for evaluating drug effects. The testing of CA-4 on zebrafish is so far lacking and assessment of CA-4 on this model will provide with new insights of understanding the function of CA-4 on angiogenesis, the toxicities and side effects of CA-4. We discovered that 7-9 ng/ml CA-4 treatments resulted in developmental retardation and morphological malformation, and led to potent angiogenic defects in zebrafish embryos. Next, we demonstrated that intraperitoneal injection of 5, 10 and 20 mg/kg CA-4 obviously inhibited vessel plexus formation in regenerated pectoral fins of adult zebrafish. Interestingly, we proved that CA-4 treatment induced significant cell apoptosis in central nervous system of zebrafish embryos and adults. Furthermore, it was demonstrated that the neuronal apoptosis induced by CA-4 treatment was alleviated in p53 mutants. In addition, notch1a was up-regulated in CA-4 treated embryos, and inhibition of Notch signaling by DAPT partially rescued the apoptosis in zebrafish central nervous system caused by CA-4.


Assuntos
Apoptose/efeitos dos fármacos , Neovascularização Patológica/tratamento farmacológico , Estilbenos/efeitos adversos , Animais , Sistema Nervoso Central/efeitos dos fármacos , Sistema Nervoso Central/metabolismo , Embrião não Mamífero/efeitos dos fármacos , Embrião não Mamífero/metabolismo , Regulação da Expressão Gênica no Desenvolvimento/efeitos dos fármacos , Modelos Animais , Morfogênese/efeitos dos fármacos , Neovascularização Patológica/metabolismo , Receptores Notch/metabolismo , Transdução de Sinais/efeitos dos fármacos , Proteína Supressora de Tumor p53/metabolismo , Regulação para Cima/efeitos dos fármacos , Peixe-Zebra/metabolismo , Proteínas de Peixe-Zebra/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...